Robus Technologies

Autoclave High Pressure Steam Strilizer

Home » AutoClave » Vertical Autoclave » High Pressure Steam Strilizer

High Pressure Steam Strilizer

Model #: Autoclave

Brochure :Download Brochure


Features

Saving The Installation Space
The main body is very compact owing to the design which provides through installation space saving.  In addition, installation space at the side of the main body which is required for models employing a slide-open lid, which is not necessary at ROBUS autoclaves top-open lid.  Even when several Robus autoclaves are installed side-by-side, the necessary installation space is minimized.

Cooling Fan
A rapid air-cooling function (vessel-cooling fan) permitting reduction of chamber cool down time is provided as a standard feature.  This is most appropriate for lowering the temperature rapidly on completion of the cycle.  The time required for lower the temperature is much reduced by employment of the cooling fan in comparison with natural cooling.

Display
The LCD display shown working status for easy monitoring.  The process being performed is indicated by an LCD indication lamp blinking in red.  The illuminated display on the operating panel shown in the picture is different from the actual display at the time of operation.

Timer Function
The operation starting time can be preset easily.  By presetting the start of operation, otherwise wasted periods at night or early morning, can be used effectively.

Lid Interlock
A safety device (lid interlock mechanism) for locking the lid during operation is provided.  A high level of safety is assured to prevent unanticipated accidents.

Interface control
Automatically display the latest sterilization program after the startup. Start up the sterilizer with the click of the START button.
Possess status flow chart, showing the current sterilization mode, sterilization status and completed sterilization program. Programs to be processed are designed with the countdown function, making the residual time extremely clear.
Users can inquire concrete parameters of the current program with the click of the
CONFIRM button.

Optional parts
Article temperature sensor, printing function.

Model      
     
RTA60 RTA85 RTA110
Capacity(L) 60 85 110
Sterilization mode Solid mode: 
Heating-Sterilizing-Exhausting and air cooling
Liquid mode:
Heating-sterilizing-Precooling-Steam exhausting
Waste Mode:
Heating-Sterilizing-Steam exhausting and air cooling
Agar Mode:
Heating-Melting-Warming
Chamber material SUS304
Rated power supply 220V/50Hz
Rate power(W) 2900 4600 4600
Sterilization temperature 105—138℃
Range of sterilization time 1—300minutes
Melting temperature 60—100℃
Range of melting time 1—300minutes
Warming temperature 45—60℃
Range of melting time 1—9999minutes
Preset range of cooling lock OPEN temperature 40-99℃ for solid and agar modes and 40-80℃ for liquid and waste modes
Preset range of steam exhausting temperature 73—104℃
Exhausting mode Fully automatic internal discharging
Embedded with a steam trapping bottle
Way of opening lid Flip type
Preset range of timer 0 minute-6 days delayed
Display range of pressure gauge 0-0.6MPa
Preset temperature of chamber lid opening presettable
Rated working pressure 0.27 MPa
Controller “inspiration” fast-speed microcomputer intelligent control system
Safety device “eight-column evenly distributed” interlocking device, electric double inner locks, dry scorch protection, over pressure protection, safety valve, over temperature protection, over current and short circuit protection, leakage protection, cooling lock, anti-scald chamber cove rand bench, automatic troubleshooting
 Accessories drainage hose, water plate, exhaust bottle
  Two stainless steel baskets Two stainless steel baskets Three stainless steel baskets